Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	22
Date	08/07/14
Start Time	15:39:29
Diameter Midpoint
 11.3	25127.3
 11.8	53652.3
 12.2	61700.7
 12.6	70588.1
 13.1	80039.3
 13.6	95678.9
 14.1	112457
 14.6	126945
 15.1	149430
 15.7	169055
 16.3	197118
 16.8	223973
 17.5	251469
 18.1	281597
 18.8	320359
 19.5	357156
 20.2	401494
 20.9	426234
 21.7	469372
 22.5	514587
 23.3	559883
 24.1	601748
 25.0	652495
 25.9	699458
 26.9	745431
 27.9	786517
 28.9	832691
 30.0	867658
 31.1	907341
 32.2	932820
 33.4	948101
 34.6	954229
 35.9	937153
 37.2	926856
 38.5	896447
 40.0	862812
 41.4	817846
 42.9	761223
 44.5	698961
 46.1	632930
 47.8	562720
 49.6	488065
 51.4	419770
 53.3	356506
 55.2	298342
 57.3	248768
 59.4	202785
 61.5	161051
 63.8	126668
 66.1	97988.8
 68.5	74523.3
 71.0	56024.3
 73.7	41685.4
 76.4	30052.2
 79.1	21535.7
 82.0	15391.2
 85.1	10550.7
 88.2	7274.21
 91.4	5185.5
 94.7	3543.66
 98.2	2365.35
101.8	1555.04
105.5	1080.35
109.4	783.85
113.4	508.623
117.6	358.199
121.9	301.128
126.3	246.572
131.0	210.809
135.8	204.304
140.7	162.042
145.9	124.89
151.2	108.066
156.8	110.306
162.5	106.836
168.5	118.765
174.7	92.2315
181.1	106.191
187.7	81.5845
194.6	67.4028
201.7	83.8771
209.1	99.5867
216.7	67.0935
224.7	115.858
232.9	74.6548
241.4	47.5072
250.3	75.1998
259.5	67.7371
269.0	37.1426
278.8	38.0718
289.0	73.4752
299.6	40.5036
310.6	58.2955
322.0	60.0168
333.8	20.9774
346.0	22.7201
358.7	28.9693
371.8	25.5877
385.4	30.0485
399.5	33.0061
414.2	23.4708
429.4	40.3413
445.1	18.6244
461.4	14.5594
478.3	26.5919
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7269
High Voltage	9924.88
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	32.6007
Mean(nm)	33.9282
Geo. Mean(nm)	31.8123
Mode(nm)	34.5989
Geo. Std. Dev.	1.43901
Total Concentration(#/cm)	2.3649e+007
Comment	